phone Phone
+6281290773137
close
menu

CV. Andalan Prima Sejahtera

sql
210VGP Atomic Absorption Spectrophotometer
Hover to Zoom

Jual 210VGP Atomic Absorption Spectrophotometer



Spesifikasi 210VGP Atomic Absorption Spectrophotometer

Features

210VGP Atomic Absorption Spectrophotometer

  • Stable, Reliable, & Easy to use.
  • 3 lamp power supply, (1 internal 2 external)
  • High energy optical design for better As & Se results
  • Compact and lightweight 39"L x 11"W x 12"H; 50 lbs
  • Rugged military grade design stands up to years of abuse.
  • D2 Background correction
  • Free Buck Analyst Software
  • Low cost consumables and maintenance
  • Made in the USA
  • Leasing available for domestic customers
  • Free in-house training for the life of the instrument

The 210VGP is shipped ready for use. All operating conditions are pre-loaded in the internal computer, including lamp settings, secondary wavelengths, and alternate methods of analysis for over 60 elements by flame, furnace, or hydride techniques. The three lamp turret has individual controls for alignment and standby mode to keep lamps warm. Direct report generation to a printer or data linking to the Free Buck Analyst* software package is easily done using the parallel and RS-232 serial ports.

The Buck 210VGP is a high energy, microprocessor controlled, single beam atomic absorption spectrophotometer. Solid state electronics and simple optics provide the basis for our superior stability and sensitivity. The Ebert mount monochromator and user-selectable bandwidth gives the system maximum flexibility. Our short-path dynamic nebulizer/burner configuration is highly efficient. An inert needle, precisely positioned in a high flow venturi, delivers the sample to the corrosion proof impact bead. This results in a tremendously high nebulization effect for all types of sample matrices.

Deuterium Background Correction

This is the oldest and still most commonly used technique, particularly for flame AAS. In this case, a separate source (a deuterium lamp) with broad emission is used to measure the background absorption over the entire width of the exit slit of the spectrometer. In the 210VGP & Accusys 211 the deuterium lamp is in-line with the hollow cathode lamp, thus eliminating the need for a double beam system. The benefits of a single beam system are more energy, smaller size, lower cost, and a more sensitivity.

Specifications

Wavelength Range:190 to 900nm, Accuracy ± 0.2nm, Precision ± 0.1nm
Monochromator / Optics:250mm Ebert mount, 600 lines/mm grating, 0.2-0.7-2.0nm bandpass
Hollow Cathode Lamp Supply:Triple HCL power supply; 3 to 75 mA peak in NORMAL mode, 3 to 750mA in GIANT PULSE mode. The 205 has a three lamp design.
Background Correction:Deuterium - In-Line (see-through) configuration, pulsed illumination, hot cathode, variable frequency, corrects from 190-350nm (0.7nm slit). Variable Giant Pulse - Self-reversing HCL currents up to 750 mA with pulse time from 10 to 200 microseconds, corrects from 190-900nm. The 205AAS Does not feature D2 Background correction
Burner / Nebulizer:Polypropylene spray chamber with pre-mix burner and high efficiency adjustable nebulizers (SS), Titanium burner heads for Air/Acetylene, Argon/Hydrogen and Nitrous Oxide/Acetylene operation.
Microprocessor:Computer control by 80C188 chip, 8/16 bit operation, 12/24 MHz clockspeed; non-volatile SRAM storage of >200 method files.
Integration / Response Range:User selectable times from 0.5 to 10 seconds for continuous (flame) and transient (furnace, hydride) signals.
Calibration:Automatic, weighted least squares fit to 1st, 2nd, 3rd, or 4th order functions, up to 8 points.
Display:16-line backlit liquid crystal display for all text and graphics
Output Modes:LCD display, IEEE-488 Parallel port for dot-matrix printer, RS-232 Serial port
Dimensions / Weight:39"L x 11"W x 12"H; 50 lbs (81 lbs shipping weight)
Power Supply:100-240 VAC operating range, 50/60 Hz AC, <150 watts