phone Phone
+6281290773137
close
menu

CV. Andalan Prima Sejahtera

sql
6850 Double Beam Spectrophotometer
Hover to Zoom

Jual 6850 Double Beam Spectrophotometer



Spesifikasi 6850 Double Beam Spectrophotometer

Description

6850 Double Beam Spectrophotometer

Double beam spectrophotometer with highly stable optics
Variable spectral bandwidth 0.5, 1, 2, 4, 5nm
Integrated user interface
Conforms to European Pharmacopeia requirements
Jenway Prism PC software included as standard
Extensive range of accessories available

The new 6850 introduces the first double beam spectrophotometer with a variable spectral bandwidth into the Jenway range. The highly stable optics and two detectors measure the sample and reference simultaneously optimising measurement accuracy. The 6850 has measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA/RNA and protein analysis. 

Jenway Prism PC software is supplied as standard and offers additional functionality, extensive post-measurement tools, unlimited results saving and easy export of data. The 6850 is ideal for quality control, general research, pharmaceutical, biochemical and clinical laboratory applications.


Technical Specifications

Parameter6850
Wavelength range190 to 1100nm
Wavelength resolution0.1nm
Wavelength accuracy± 0.3nm (at 0.5 and 1nm bandwidth)
Wavelength reproducibility±0.2nm
Spectral bandwidthVariable 0.5, 1, 2, 4, 5nm
Photometric range-0.3 to 3.0A, 0 to 200T
Photometric accuracy± 0.002A (0-0.5A), ±0.3T (0-100T)
Photometric reproducibility±0.001 Abs (0 to 0.5 Abs), ±0.002 Abs (0.5 to 1.0 Abs), 0.15T (0-100T)
Resolution0.1T, 0.001A
Stray light0.05T at 220 and 360nm
Noise0.0005A
Stability± 0.001Ah at 500nm after 15 min warm up
Multi-wavelengthUp to 10 wavelengths, up to 20 wavelengths with PC software
CalculationsRatio, difference, formulae with factors
Spectrum rangeAny range between 190 and 1100nm
Scan speed100 to 2000nm min
Scan interval0.1, 0.2, 0.5, 1, 2 or 5nm
KineticsUp to 12 hours with time intervals of 0.1, 0.2, 0.5, 1, 2, 5, 10 or 30 seconds
AnalysisSlope and formula of line of best fit between any two points
Quantitation pointsUp to 3 wavelengths
Quantitation CalibrationBlank with up to 10 standards or factor
Concentration range0-99999
CalibrationBlank with standards or factor
DNADNA Ratio, concentration, A320 correction
Light sourceTungsten halogen and Deuterium lamps
Lamp changeover325 to 370nm selec table
OutputsUSB and parallel
Operating system:Windows 2000, XP, Vista, Windows 7
Electrical supply120VA, 220110V, 5060Hz
Size (w x d x h)600 x 450 x 200mm (23.6 x 17.7 x 7.9in)
Weight22 kg (48.4 lbs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 