Spesifikasi AccuRef 30 Copper/Copper Sulfate (Splice-able) - M.C. Miller Cat. 14628

M.C. Miller AccuRef 30 Copper/Copper Sulfate (Splice-able)

Item Number: 14628


Features & Benefits

All hardware components included for onsite cable splicing (silicone sealant & PVC cement to be supplied by the customer)

Any customer-supplied cable can be used having a maximum outside diameter of 0.4 in (10 mm) and a maximum wire size of # 8 AWG (10 mm²)

Copper / copper sulfate electrode has a design lifetime of 30 years (AccuRef 30) and a -4°F (-20°C) freezing temperature

Moisture absorbent ceramic tip has a large electrical contact area of approximately16.4 inches² (approx. 105.8 cm²)

Electrode contains 80 g of high purity copper and 500 ml of saturated copper sulfate gel

Electrode is 2.77 inches (7.04 cm) in diameter at its maximum, is 15.0 inches long (38.1 cm) and weighs 3.9 lbs (1.77 kg)

Additional Information

These products must be installed according to the installation instructions provided.

These products are not guaranteed to maintain their calibration in all soil environments and it is incumbent on the customer to test their soil for the presence of any potential chemical contaminants prior to installation of these products. The M. C. Miller Company has not tested these products with regard to the effects of specific (potential) chemical contaminants on their calibration.

These products are not designed for submersion applications.


Specifications

Active electrical contact surface area: approx. 16.4 inches² (105.8 cm²)

Half-cell materials: 99.99% copper and saturated copper sulfate gel electrolyte

Max. diameter: 2.77 inches (7.04 cm)

Overall length (not including cable): 15.0 inches (38.1 cm)

Weight: approx 3.9 pounds (1.77 kg)

Important Notes:

These products must be installed according to the installation instructions provided

These products are not guaranteed to maintain their calibration in all soil environments and it is incumbent on the customer to test their soil for chloride ion content and for the presence of any other potential chemical contaminants prior to installation of these products.The M. C. Miller Company has not tested these products with regard to the effects of specific (potential) chemical contaminants on their calibration.

These products are not designed for submersion applications.


Copper Earthing Electrode

Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Minta Penawaran
Produk Siap di Pesan
Rp 0
1