Spesifikasi Bacharach 0024-8518 Fyrite Insight Plus Hand-held Combustion Analyzer
Bacharach 0024-8518 Fyrite Insight Plus Hand-held Combustion Analyzer
Fyrite® Insight® Plus Reporting Kit 0024-8518 (N. Amer. Part Number)
The Insight Plus is the perfect instrument for busy residential / light-commercial technicians who need to ensure safe operating conditions and determine combustion efficiency.
All-in-one instrument makes combustion tuning fast and simple with readings for O2, CO, CO2, combustion efficiency, temperature and draft
Industry-exclusive Tune-Rite HVAC assistant analyzes combustion data and provides real-time troubleshooting suggestions
Automatic sensor protection helps technicians protect the analyzer in harsh environments, extending sensor life
Long life O2 sensor with 3 year warranty reduces maintenance costs and downtime
Quick and easy sensor replacement in the field reduces downtime and doesn’t require calibration gas
Combustion App allows users to quickly create custom reports with comments and send via email (available for Android & iOS)
Specification
Sensors: Up to 2
Measuring Range: O2 0 To 20.9%, CO 0-4000 ppm
Stack Temperature: -4 to 1202 °F (-20 to 650 °C)
Draft / Differential Pressure: ± 40 inH2O (±10 mbar)
User Interface: Color LCD w/ backlight
Display Size: 2.8 in (72 mm)
Power: 4 × Alkaline Batteries
Run Time: 15 Hours (Alkaline Batteries)
Warm-Up Time: 30 To 60 Seconds
Digital Communications: USB 2.0 (mini-B), IrDA
Ambient Temperature: 23 to 113 °F (-5 to 45 °C)
Humidity: 15 to 90% RH (non-condensing)
Altitude: 1 ATM ± 10%
Product Dimensions (L×W×H): 8" × 3.6" × 2.3" (20.3 × 9.1 × 5.8 cm)
Product Weight: 1 lb. (0.45 kg) including batteries
Fuel Equations: Natural gas, coal, oil 2/4/6, wood, kerosene, propane, butane, LPG, B5, KOKS, LEG, biofuel, +2 optional custom fuels
Approvals: CE, EN 50379-1, EN 50379-3
Internal Memory: 100 Records
Warranty: Instrument: 2 Years (Including Sensors), O2 Sensor: 3 Years (Long-life Sensor, If Equipped)
Printer: IrDA + Bluetooth Printer (Optional)
Country of Origin: United States
Reporting kit adds:
IrDA wireless printer
USB cable
Fyrite® User Software
4 additional AA batteries