Fluke 724 Temperature Calibrator

  • Easy to read dual display lets you view input and output simultaneously
  • Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters
  • Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters
  • Perform fast linearity tests with 25% and 100% steps
  • Execute remote tests with auto step and auto ramp
  • Power transmitters during test using loop power supply with simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Compact, streamlined shape makes it easy to carry
  • Rugged, reliable design stands up to field use
  • Backlight lets you work in poor light
  • Large battery capacity of four AA cells
  • Battery door for easy changes
Measurement Accuracy
Voltage DC
30.000 V0.02%+ 2 counts (upper display)
20.000 V0.02%+ 2 counts (lower display)
100.00 mV0.02%+ 2 counts
-10.00 mV to 75.00 mV0.025 % + 1 count (via TC connector)
Current DC
24.000 mA0.02%+ 2 counts
Resistance
0.0 to 400.0 Ω0.1Ω (4-wire), 0.15Ω (2- and 3-wire)
401 to 1500 Ω0.5Ω (4-wire), 1Ω (2- and 3-wire)
1500 to 3200 Ω1Ω (4-wire), 1.5Ω (2- and 3-wire)
Source Accuracy
Voltage DC
100.00 mV0.02%+2 counts
10.000 V0.02%+2 counts
-10.00 mV to 75.00 mV0.025 % + 1 count (via TC connector)
Resistance
15.0 to 400.0 Ω0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω0.5 Ω(excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω1 Ω(excitation current 0.05 to 0.4 mA)
RTDs and Thermocouples
Measure Accuracy:
NI-120
PT-100 (385)
PT-100 (393)
PT-100 (JIS)
PT-200 (385)
PT-500 (385)
PT-1000 (385)
Resolution:
J:
K:
T:
E:
R:
S:
B:
L:
U:
N:
Resolution
XK
BP
0.2 °C
0.33 °C
0.3 °C
0.3 °C
0.2 °C
0.3 °C
0.2 °C
0.1 °C
0.7 °C
0.8 °C
0.8 °C
0.7 °C
1.8 °C
1.5 °C
1.4 °C
0.7 °C
0.75 °C
0.9°C
J, K, T, E, L, N, U: 0.1 °C, 0.1 °F B, R, S: 1 °C, 1 °F
0.6°C
1.2°C
Source Accuracy:
NI-120
PT-100 (385)
PT-100 (393)
PT-100 (JIS)
PT-200 (385)
PT-500 (385)
PT-1000 (385)
Resolution:
Note:
J:
K:
T:
E:
R:
S:
B:
L:
U:
N:
Resolution
XK
BP
0.2 °C
0.33 °C
0.3 °C
0.3 °C
0.2 °C
0.3 °C
0.2 °C
0.1 °C
Accuracy stated for 4-wire measurement.
0.7 °C
0.8 °C
0.8 °C
0.7 °C
1.8 °C
1.5 °C
1.4 °C
0.7 °C
0.75 °C
0.9°C
J, K, T, E, L, N, U: 0.1 °C, 0.1 °F B, R, S: 1 °C, 1 °F
0.6°C
1.2°C
Specifications
Ramp Functions
Source functions:Voltage, current, resistance, frequency, temperature
RampsSlow ramp, Fast ramp, 25% step-ramp
Loop Power Function
Voltage:24V
Accuracy:10%
Maximum current:22 mA, short circuit protected
Step Functions
Source functions:Voltage, current, resistance, frequency, temperature
Steps25% of range, 100% of range
Environmental Specifications
Operating Temperature-10ºC to 55ºC
Storage Temperature-20ºC to 71ºC
Humidity (Without Condensation)90% 10ºC to 30ºC
75% 30ºC to 40ºC
45% 40ºC to 50ºC
35% 50ºC to 55ºC
Safety Specifications
Safety RatingCSA C22.2 No. 1010.1:1992
EMCEN50082-1:1992 and EN55022:1994 Class B
Mechanical & General Specifications
Size96 x 200 x 47 mm
Weight650 g
BatteriesFour AA alkaline batteries
WarrantyThree years
Battery Life25 hours typical
Shock & VibrationRandom, 2G, 5-500 Hz

Tech Specs

Test Equipment General Attributes

Unique FeaturesThe dual display lets you source temperature and view loop current at the same time. Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters. Execute remote tests with auto step and auto ramp.
Warranty3 YEARS
Safety ApprovalCSA
Product Weight1.433 LBS
Product Height1.85 IN
Product Length7.87 IN
Product Width3.77 IN
Data LoggingNo
HTS/Schedule B Number9030.39.0100
ECCN NumberEAR99
Calibration IncludedNIST Calibration
Power Supply VoltageBattery Powered

Multimeter