GENRAD 1531-AB STROBOSCOPE
Hover to Zoom

31 Okt 2019
United States
1 unit
IDR CALL

Spesifikasi

1531 Stroboscope Uses 

The GenRad 1531 Strobotac electronic stroboscope is a small portable flashing-light source used to measure the speed of fast-moving devices or to produce the optical effect of stopping or slowing down high-speed motion for observation. 

A few of this instrument's many uses are:

  • 1. Observation and speed measurement of gears,cams, linkages, shuttles, spindles, motor rotors, and any other elements having repetitive motion.
  • 2. Observation of vibrating members, fuel-nozzle spray patterns, and vibrations of components undertest in wind tunnels.
  • 3. High-speed photography of repetitive or nonrepetitive motion


1531 Stroboscope Description

The GenRad 1531-AB Strobotac electronic stroboscope includes a strobotron lamp and reflector assembly, an electronic pulse generator that controls the flashing rate, and a line-operated power supply. The flashing-rate range of 110 to 25.000 flashes per minute is divided into three direct-reading ranges; to avoid reading errors, only the particular range in use is illuminated. The rpm control is concentric with the range selector, and its large diameter provides precise control of the flashing rate. The flash lamp can be triggered externally to "stop" motion for photography. The combination of the Type 1531-P2 Flash Delay and the 1536-A Photoelectric Pickoff can be used as an external triggering source, which also provides an adjustable delay of the stroboscope flash with respect to the triggering pulse from the photoelectric pickoff. 

A built-in calibration system within the GenRad 1531 Stroboscope uses the power-line frequency for quick, easy check and readjustment of the flashing-rate calibration. The strobotron flash lamp and reflector assembly pivots in a plane perpendicular to the panel and swivels 360 degrees on its own axis. 

 

Specification

Calibration:Accurately calibrated flash rates to 25,000 per minute.
Flash Rate: In flashes per minute: 110 to 25,000 in 3 ranges; speeds up to 250,000 rpm can be measured.
Accuracy: 1% of reading after calibration on one range against 50-to-60 Hz line frequency.
External Trigger:  Input and output connections are phone jacks. 
INPUT: Contact opening, pulse > +6 V pK-pk. or sinewave> 2 V rms for f > 5 Hz. 
OUTPUT:Negative pulse > 500 to1000 V

 Duration Energy watt-seconds Beam Intensity (candela)

at 690 fpm 

3 µs 

0.5

11x10'6

at 4170 fpm 

1.2 µs 

0.09

3.5x10'6

at 25,000 fpm 

0.8 µs 

0.014

0.6x10'6

 

Alat Laboratorium Umum

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
phone Telepon
Minta Penawaran
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot