GREENLINE 6000 - Hand-held industrial combustion gas analyzer with 6 sensors
GREENLINE 6000 - Hand-held industrial combustion gas analyzer with 6 sensors
Hover to Zoom

Jual GREENLINE 6000 - Hand-held industrial combustion gas analyzer with 6 sensors



Spesifikasi GREENLINE 6000 - Hand-held industrial combustion gas analyzer with 6 sensors

GREENLINE 6000 - Hand-held industrial combustion gas analyzer with 6 sensors

GreenLine 6000 is a flue gas analyzer that measures up to 6 gases: O2, CO, NO, NO2, SO, CxHy with electrochemical sensors, and can calculate others like CO2. It accepts up to 10 different preloaded fuels. Further fuels can be added using GasConfig PC software.

The gas analyzer is made of two parts communicating through cable or Bluetooth protocol: the Main Control Unit (MCU) and the Remote Control Unit (RCU). The MCU takes in charge gas analyzis while the RCU is used to display the measured data, store the analyzis in its internal memory, print out any data using the built-in impact printer and transfer data to computer.

GreenLine 6000 provides various additional functionalities available in option to enable comprehensive combustion gas analyses:

  • Air and boiler surface temperature measurements, using specific probes
  • Draft measurement
  • Automatic CO sensor internal protection from high CO level by extension of the measuring range up to 10% CO
  • Flow measurement: Measuring the flow of gas extracted from the boiler and adjusting the pump in order to obtain a constant sampling volume
  • Differential pressure measurement:  Measuring pressure at the burner and checking stack draft
  • Two 4-20 mA inputs
  • Smoke index measurement: Checking the presence of soot in gas pipes behind the heat exchanger, with a manual smoke pump, smoke index reference table and paper filter.
  • Gas velocity measurement, using a Pitot tube
  • Gas leak detection, using a leak test kit

With gas and air temperature measurements combined to gas analyzis, GreenLine 4000 will calculate the boiler efficiency, excess air and CO2 concentration.

Key features:

  • Accepts up to 6 gas sensors in different ranges, O2, CO, NO, NO2, SO, CxHy
  • Measures up to 10 different fuels in standard. Other fuels can be added using GasConfig software
  • Up to 6 sound and visual alarms if set limits of gas type and levels are exceeded.
  • DBGas 2004 software package allows the operator to easily manage all of the data & analyzis information

 

Measured parameterRangeResolutionGreenLine 6000
O2From 0 to 25% vol.0.1 %EC
COFrom 0 to 8000 ppm1 ppmEC
COFrom 0 to 20000 ppm1 ppmEC
CO LOWFrom 0 to 500 ppm0.1 ppmEC
COFrom 0 to 10%0.01%EC
CO2From 0 to 99.9%0.1%Calc
NOFrom 0 to 4000 ppm1 ppmEC
NO LOWFrom 0 to 500 ppm0.1 ppmEC
NOxFrom 0 to 4000 ppm1 ppmCalc
NO2From 0 to 1000 ppm1 ppmEC
NO2 LOWFrom 0 to 100 ppm0.1 ppmEC
SO2From 0 to 4000 ppm1 ppmEC
CxHyFrom 0 to 5%0.01%Pellistore
H2SFrom 0 to 1000 ppm1 ppmEC
EfficiencyFrom 1 to 99.9%0.1%Calc
Excess airFrom 1 to infinite0.01%Calc
Delta P±100 hPa0.01 hPa
Tair/Tgas-10...100°C / 0...1000°C0.1°CPt100 / Tc K
Calc

Further features

Zero calibrationAutomatic calibration procedure at instrument power-on. Fresh air inlet with electrovalve and separate pneumatic circuit
Self-diagnosisSensor efficiency test with diagnostic page
Gas level alarmsProgrammable from PC with GasConfig software
Sampling pump2.2 l/min - 220 mbar with electronic flow controller
Smoke measurementUsing the heated probe or the optional external manual pump
Index memory store and printout capability as standard

General specifications

SizeMCU: 455 x 205 x 365 mm
RCU: 115 x 90 x 330 mm
WeightMCU: 10 kg
RCU: 0.9 kg
Power supply110 / 230 VAC (50/60 Hz)
BatteryType: Rechargeable 7.2 Ah
Battery life: 10 hours continuous use
Communication portsRS 232
Bluetooth
Internal test memoryUp to 1,000 complete analysis data points structured by Tags

Environmental specifications

Operating reference rangeFrom -5°C to +45°C (up to 50°C for short time)
Storage temperature limitsFrom -20 to +60°C (3 months max. at temperatures exceeding the operational limits)

Detektor Gas