menu

CV. Andalan Prima Sejahtera

sql
HANNA HI981420 GroLine Hydroponic Nutrients Monitor for pH EC TDS and Temperature
Hover to Zoom

IDR CALL

Spesifikasi

HANNA HI981420 GroLine Hydroponic Nutrients Monitor for pH, EC, TDS, and Temperature

Features at-a-glance

 

·         3 sensors combined in a single rugged probe body: pH electrode with renewable cloth junction, amperometric EC/TDS sensor, and an internal temperature sensor for temperature compensated readings

·         IP65 rated enclosure: designed to withstand harsh grow environments

·         Wide pH Range: measure pH from 0.00 to 14.00 pH

·         Selectable EC to TDS/ppm conversion factor: choice of either a 0.5 or 0.7 conversion factor

·         Automatic Temperature Compensation: all readings are compensated for variations in temperature, temperature displayed in oC or oF along with pH, EC or TDS reading

·         Large LCD with plant-friendly green backlighting: LCD can display all three essential hydroponic nutrient measurements at one time, a 3-second cycle of single measurements, or a real-time graph screen with options for measurement selection and log recall

·         Data logging for 30 days: logs every 15 minutes for last 30 days, stores min, max, and average values

·         Data transfer: USB-C port for easy data transfer to memory stick or PC

·         High and low alarms: warns when your nutrient solution is out of desired range by flashing display and message

  •  Ambient light sensor: for automatic LCD dimming

 

          Specification

 

pH Range

0.00 to 14.00 pH; 0.0 to 14.0 pH

pH Resolution

0.01 pH; 0.1 pH

pH Accuracy

±0.05 pH; ± 0.1 pH

pH Calibration

one or two-point calibration (using pH4.01,7.01, 10.01 buffers) using auto buffer recognition; one-pointcalibration using quick calibration solution

pH Temperature Compensation

automatic (0.0 to 60.0ºC/ 32.0 to140.0°)

 

EC Range

0.00 to 10.00 mS/cm

EC Resolution

0.01 mS/cm

EC Accuracy

±0.1mS/cm (0.00 to 5.00mS/cm);±0.2mS/cm (5.00 to 10.00mS/cm)

EC Calibration

one-point at 1.41 mS/cm or 5.00 mS/cmusing auto standard recognition; one-point calibration using quickcalibration solution

TDS Range

0 to 5000 ppm (TDS conversion factor0.5 (500 CF)); 0 to 7000 ppm (TDS conversion factor 0.7 (700 CF))

TDS Resolution

10 ppm

TDS Accuracy

±2% f.s.

EC/TDS Temperature Compensation

automatic

Temperature Correction Coefficient

β set at 1.9%/°C

EC to TDS Conversion Factor

TDS conversion factor 0.5 (500 CF);TDS conversion factor 0.7 (700 CF)

 

 

Temperature Range

0.0 to 60.0°C / 32.0 to 140.0°F

Temperature Resolution

0.1°C / 0.1°F

Temperature Accuracy

±0.5°C /±1°F

 

Alarm Relay Set Point

high and low with enable/disableoption for all parameters

 

Multi-parameter Probe

HI1285-8 pH/EC/TDS/temperaturepolypropylene body, pre-amplified multiparameter probe with internaltemperature sensor DIN connector and 2 m (6.6’) cable

Logging Type

automatic logging for last 30 days at15 minute interval

Connectivity

USB Type-C for flash drive orcompatible device

GLP

last 5 pH and EC calibrations

Display

128 x 64 pixel B/W LCD with greenbacklight

Power Supply

12VDC adapter (included)

Environment

-5 to 50°C (23 to 122°F); RH max 95%non-condensing

IP Rating

IP65

Dimensions

125 x 185 x 38 mm (4.92 x 7.28 x1.49”)

Weight

333g ( 11.7oz.)

Ordering Information

HI981420 is supplied with: HI1285-8multi-parameter probe, HI50036-0 Quick Cal buffer solution sachet (2),HI700661P electrode cleaning solution sachets for agriculture (2), 12VDCadapter, calibration certificates for both meter and probe, and instruction manual.


Alat Laboratorium Umum

Untuk keterangan lebih lanjut, silahkan download PDF ini :

phone Telepon
Minta Penawaran
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT