EXOTEK InfraRed Thermometer IRT-1001
Hover to Zoom

Jual EXOTEK InfraRed Thermometer IRT-1001



Spesifikasi EXOTEK InfraRed Thermometer IRT-1001

InfraRed Thermometer IRT-1001

Application

Wide range application:

Food preparation, Safety and Fire inspectors, Plastic molding, Asphalt, Ma- rine and screen printing, measure ink and dryer temperature, Diesel and Fleet maintenance.

Field of View

Meter’s field of view is 10:1, meaning that if the meter is 10 inches from the target, the diameter of the object under test must be at least 1 inch. Other distances are shown below in the field of view diagram. Refer to the chart printed on the meter for more information.

Features:

  • Precise non-contact measurements
  • Built-in laser pointer
  • Automatic selection range and Resolution to 0.1ºor 1º
  • °F/°F switchable button
  • Automatic Data Hold & Auto power off
  • The meter at 10 inches away measure 1 inch target
  • Backlit LCD display
  • MAX/MIN temperature measurement Function

 

Specification

MEAS. RANGES

-50.0℃ to 760.0℃/-58.0℉to 1400℉

SAMPLE RATE

Less than 1 second

OVER RANGE INDICATION

LCD will show “OL”and”-OL”

POLARITY

Automatic (no indication for positive polarity); Minus (-) sign for negative polarity.

EMISSIVITY

0.95 fixed value

FIELD OF VIEW

D/S = Approx. 10:1 ratio (D = distance, S = spot)

(Has 80% encircled energy at the focal point)

DIODE LASER

Output <1mW, Wavelength 630~670nm,class 2 (II) Laser

product

SPECTRAL RESPONSE

6~14um

POWER OFF

Automatic shut off after 7 seconds, approx.

OPERATING TEMP.

0℃ to 50℃ (32℉to 122℉)

STORAGE TEMP.

-20oC to 60oC(-4oF to 140oF)

RELATIVE HUMIDITY

10%~90%RH operating, <80%RH storage

POWER SUPPLY

9V battery, NEDA 1604A or IEC 6LR61, or equivalent

WEIGHT

180g.

SIZE

82 x 41.5 x 160mm

 

Range

Resolution   Accuracy

-50.0oC to 760.0 oC

-50.0oC  to -20.0 oC                      + 5 oC;

                                 0.1 oC

-20.0oC to 200.0 oC

 

± 2% of reading or ± 2ºC;

200.0 oC to 760 .0oC

± 2.5% of reading ± 2ºC

 

Range

(Automatic selection 0.1 ℉/ 1℉)

Resolution   Accuracy

-58.0℉to1400 ℉

-58.0 ℉ to -4.0 oC ℉                       + 9 ℉;

                                  0.1℉

-4.0℉to 200.0 ℉

 

± 2% of reading or + 4 ℉;

200.0℉ to 999.9℉

± 2.5% of reading +4 ℉;

1000℉ to 1400℉

1℉

 

 

Note:

Accuracy is given at 18 oC to 28 oC (64 oF to 82 oF), less than 80%RH.

Field of View:

Make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make sure the target is at least

twice as large as the spot size.

 

Emissivity:

0.95 fixed value