phone Phone
+6281290773137
close
menu

CV. Andalan Prima Sejahtera

sql
Jenway - 62 Series Fluorimeters
Hover to Zoom

Jual Jenway - 62 Series Fluorimeters



Spesifikasi Jenway - 62 Series Fluorimeters

Jenway - 62 Series Fluorimeters

High quality optics: pulsed xenon lamp and Total Energy Transfer (TET)
• Intelligent Filter Modules ensure correct filters are fitted for selected method
• Intuitive programming allows fast program creation
• Raw fluorescence or concentration values options
• Standard curve and kinetic functions
• Heated sample holder and sipper pump accessories
• Compatible with DataWay PC software
• 3 year warranty

Jenway offers three fluorimeter models to cover a wide range of applications and fluorscence measurements. The 6280 fluorimeter model is ideal for the most sensitive determinations with emission wavelengths up to 650nm. When higher emission wavelengths are required the 6285 fluorimeter with its red-enhanced detector is the unit of choice. For less sensitive applications and a broader wavelength range up to 1100nm the low cost 6270 fluorimeter unit is more
suitable.

With press-to-read operation and Total Energy Transfer (TET) technology the output of the high-energy xenon lamp is maximised and its expected life extended so that it should never need replacing within the normal lifetime of the unit. The high quality optics are complemented by the Intelligent Filter Modules (IFM) that are identified by the unit, generating error messages should the wrong filters be fitted or their positions be incorrect.

Each fluorimeter model offers intuitive operation with a user interface based on logical menus that can be navigated from the simple keypad. Up to 20 methods can be created without restriction and saved for future use. They can also be locked against accidental change by password entry. The permanent time and date tag on every stored reading supports Good Laboratory Practice, while calibration reminders and operator identity can also be entered to support conformance and traceability of results.

All fluorimeter models are powered from an external, universal mains adapter suitable for use from 90V to 230V.


Features

 

Feature62 Series Fluorimeter
Wavelength selec tionIntelligent Filter Modules (IFM)
Light sourcePulsed Xenon lamp with press-to-read operation
Expected life of lampNo replacement required in normal operation
Raw fluorescence readingsYes
Concentration standard curveBlank + up to 6 standards
Kinetics, timed optionIn both raw fluorescence and concentration modes
Kinetics options1 reading every 3 to 999 seconds
No. methods stored20
No. results stored100 per method
GLPMethod lock with password access. Time and date stamped results. Last calibration date and time stored. Calibration interval set. Calibration due reminder. User ID
OutputsRS232
PC softwareCompatible with DataWay (option)
Sample handling10mm square cuvette holder (standard). Heated sample holder (option). Sipper pump (option)
Power supply90 to 230V universal mains adapter 12V DC input
Size (w x d x h)365 x 272 x 160mm
Weight6kg

 


Technical Specification

 

Parameter627062806285
Wavelength range190 to 1100nm190 to 650nm190 to 850nm
Sensitivity11µg/ml<1ng/ml<1ng/ml
Dynamic range15.2x1045.2x1065.2x106
DetectorPhotodiodePMT2PMT2

 

Alat Laboratorium Umum