CV. Andalan Prima Sejahtera

sql
K23792-OS KV5000 Kinematic Viscosity Bath with Optical Flow Detection System
Hover to Zoom

31 Okt 2019
United States
1 unit
IDR CALL

Spesifikasi

Test Method

Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products. Calibrated capillary viscometers are used to measure flow under gravity or vacuum at precisely controlled temperatures.

Specifications

Conforms to the specifications of: 

ASTM D445, D2170, D6074, D6158; IP 71, 319; ISO 3104; DIN 51550; FTM 791-305; NF T 60-100

Temperature Control Range: Ambient to 150°C (302°F); sub-ambient to 10°C with external cooling

Display: 0.1 °C / 0.1 °F resolution, calibrate to 0.01 °C / 0.01 °F

Control accuracy and uniformity: Exceeds ASTM requirements throughout the operating range

Timing: Integrated timing function within Touch Screen Control Panel  displayed to 0.1 seconds and accurate within 0.01%

Communication: RS232, RS485 port

Viscometer ports: Seven round 2" (51mm) ports

Bath Medium: Water or suitable heat transfer fluid

Bath Capacity:

12": 5.8 gal (22L)
18": 8.9 gal (33.7L)

Description

KV5000 model Kinematic Viscosity Baths with optical flow detection system provide automatic viscosity measurements of petroleum and petrochemical products. Includes communication and power ports for each optical detection assembly, and can utilize up to five optical assemblies. Two additional positions are available for manual viscosity measurements, and all positions can be used in the manual mode. The interchangeable Ubbelohde, Cannon®- Fenske, and Cannon®- Fenske Opaque Reverse Flow viscometer tubes are quickly installed and removed from the detection assemblies for cleaning and simple tube changes. Allows for automatic viscosity measurements and results calculation without an external PC. Motorized stirrer provides complete circulation without turbulence. Microprocessor PID circuitry assures precise, reliable temperature control within ASTM specified tolerances throughout the operating range. Simple push-button controls and dual digital displays permit easy setting and monitoring of temperature. Two place calibration offset capability is provided. Built-in cooling coil facilitates temperature control at ambient or below ambient temperatures.
 
The Kinematic Viscosity Software Package automatically downloads test data and calculates final test results from sample efflux times. Also included is a database for storing test data, determining test averages, standard deviations, and ASTM test repeatability as well as providing a method for tracking both instrument and viscometer tube calibrations.

Alat Laboratorium Umum

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Minta Penawaran
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot