phone Phone
+6281290773137
close
menu

CV. Andalan Prima Sejahtera

sql
Koehler K10191 Thin Film Aniline Point Apparatus
Hover to Zoom

Jual Koehler K10191 Thin Film Aniline Point Apparatus



Spesifikasi Koehler K10191 Thin Film Aniline Point Apparatus

Description

For aniline point and mixed aniline point determinations according to Method B. Stirs aniline-sample mixture in a borosilicate glass thin film tube suspended in a heating bath. Thin film of mixture flows over a light well illuminated by a variable 6V lamp. Adjust heating rate per specifications using accessory Powertrol Heater. When lamp filament brightens inside well, allow mixture to cool until the two phases separate as indicated by obscuring of the lamp filament. Consists of thin film tube; 400mL Borosilicate Glass beaker; cover assembly with bath stirrer; sample pump rotor and cooling coil; 6V lamp with line cord; and drive motor. Positive drive pulley system rotates sample and bath stirrers. Accessory Powertrol Heater has variable stepless control and a reference dial for repeatable control of heating rate. Porcelain refractory top plate shields 1000W heater and has a positioning well for the Borosilicate Glass bath. Low voltage receptacle in heater housing accepts line cord of 6V lamp.

Test Method

Aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures. Equal volumes of aniline and sample or sample plus n-heptane are stirred together while being heated at a controlled rate. After the two phases become miscible, the mixture is cooled at a controlled rate and the temperature at which the two phases separate is the aniline point or mixed aniline point of the sample.

Features

Conforms to ASTM D611 and related specifications

Specification

Conforms to the specifications of: 

 ASTM D611; IP 2; ISO 2977;

DIN 51775; FTM 791-3601; NF M 07-021

Bath Medium: 400mL of heat transfer fluid (355-001-001 mineral oil is suitable for this application)

Included Accessories

  • Thermometer Ferrules (2)
  • Clamps and Support Rod

Additional Accessories

  • 250-000-33F ASTM 33F Thermometer, Range: –36.5 to +107.5°F 
  • 250-000-33C ASTM 33C Thermometer, Range: –38 to +42°C
  • 250-000-34F ASTM 34F Thermometer, Range: 77 to 221°F 
  • 250-000-34C ASTM 34C Thermometer, Range: 25 to 105°C
  • 250-000-35F ASTM 35F Thermometer, Range: 194 to 338°F 
  • 250-000-35C ASTM 35C Thermometer, Range: 90 to 170°C
  • K10020 Powertrol Heater, 115V 60Hz
  • K10029 Powertrol Heater, 220-240V 50/60Hz

Electrical Requirements

115V 60Hz, Single Phase, 6.5A
220-240V 50/60Hz, Single Phase, 13.4A

Alat Laboratorium Umum

Untuk keterangan lebih lanjut, silahkan download PDF ini :