VELP CN 802 Carbon Nitrogen Analyzer
Hover to Zoom


Spesifikasi

VELP CN 802 Carbon Nitrogen Analyzer

Code Product

CN 802    230 V / 50-60 Hz     F30800090

A versatile and cloud enabled elemental analyzer able to perform precise carbon and nitrogen analysis in 4 to 5 minutes. It is the ideal solution for high throughput offering complete safety to operators.

Productive

  • Flash determination of carbon and nitrogen content
  • Determination of TCTOC (after acidification), TICTN and Carbon/Nitrogen Ratio
  • Automated analysis of preloaded samples (117 positions)
  • Totally unsupervised operation
  • Results produced 24/7/365

Precise

  • NDIR Detector (Non Dispersive Infrared) to detect Carbon concentration
  • LoGas™ TCD with no reference gas required, for Nitrogen content
  • Unmatched LOD: Carbon 0.01 mgC, Nitrogen 0.001 mg N (using He) or 0.01 mg N (using Ar)
  • RSD less than 0.5% with EDTA standard
  • Conforms to Good Laboratory Practice standard
  • Leak tests (zone or total) ensure optimum performance

Versatile

  • Operates with Argon and Helium as carrier gas without any hardware modification
  • Preinstalled methods with element selection (C,N and C/N)
  • Controllable from PC by the powerful CNsoft™ software
  • Clear and detailed reporting software
  • Data storable in multiple formats for LIMS or PC

Economical

  • Exceptionally low cost per analysis
  • Premium quality consumables
  • Low energy consumption with Stand-by and Sleeping mode
  • Lowest operator costs

Environmentally Friendly

  • Minimum possible waste & residues
  • Optimized life of consumables
  • Incorporates TEMS™ technology*
GENERAL FEATURES 
Method of analysis:Cabon/Nitrogen determination according to combustion method
Duration of analysis:4/5 minutes
Detector:N= TCD (Thermal Conductivity Detector)
C= NDIR Detector (Non Dispersive Infrared)
Sample weight:Up to 1g
Autosampler capacity:up to 4 discs, 30 positions each (up to 117 samples)
Reproducibility (RSD):< 0.5% for EDTA standards approx. 100 mg
Recovery:> 99.5%
Detection Range C:ppm - 150 mgC
Detection Range N:ppm - 200 mgN
Carrier gas:Helium or Argon
Nitrogen Detection limit (Absolute values):0.001 mg N, with Helium
0.01 mg N, with Argon
Carbon Detection limit (Absolute values):0.01 mgC
Combustion temperature:1030 °C / 1886°F
Carrier gas (He/Ar):purity 99.999% (grade 5.0)
Oxygen (O2):purity 99.999% (grade 5.0)
Carrier gas (He/Ar) pressure:2 bar
Oxygen (O2) pressure:2 bar
ConnectivityCloud via LAN or Wi-Fi
Interfaces:USB; RS232
Power:1400 W
Power supply:230 V / 50 - 60 Hz
Weight:54 kg / 119 lb
Dimensions (WxHxD):655x510x410 mm (H 690 mm with autosampler)
25.8x20.1x16.1 in (H 27.0 in with autosampler)